The ATLAS activation studies


The Inner Detector


INDUCED RADIOACTIVITY IN THE ATLAS INNER DETECTOR - TRT (file in ps)
S.A. Cetin and A. Romaniouk, ATLAS note ATL-INDET-2000-13



ESTIMATING INDUCED-ACTIVATION OF SCT BARREL-MODULES (file in ps-format)
C. Buttar, I. Dawson and A.Moraes.
Submitted to the proc. of the 7th workshop on electronics for LHC experiments, Stockholm, September 2001.



ESTIMATING INDUCED-ACTIVATION OF SCT BARREL-MODULES IN THE ATLAS RADIATION ENVIRONMENT (file in pdf-format)
C. Buttar et al.
ATLAS note ATL-INDET-2002-013 (May 2002)



GEOMETRY AND MATERIAL DESCRIPTION OF THE INNER DETECTOR
Report by I. Bedajanek
(All files in doc-format)

The TRT detector
The PIXEL detector
The SCT detector
(The amount of Silver in the SCT is too low in this report)

Link to the Prague activation and shielding web-page



MATERIAL DESCRIPTION OF THE PIXEL DETECTOR
(file in xls-format. Created on 03.12.2003.)
(file in xls-format. Created on 17.01.2002.)
Spreadsheet by M. Olcese



ACTIVATION DOSE RATE FROM THE PIXEL DETECTOR (file in pdf-format)
(Calculations using an old description of PP1)
Report by M.N. Morev

Plots by V. Hedberg from the above calculation:





DOSES FROM THE ID (VI) BEAMPIPE (file in pdf-format)
Report by V.A. Klimanov, E.I. Kulakova, M.N. Morev and V.K. Sakharov (June 2002)


Plots by V. Hedberg from the above calculation:




INDUCED RADIOACTIVITY IN THE ATLAS EXPERIMENT - AN UPDATE
(file in html-format) (file in doc-format)
Report by V. Hedberg to the CERN Radioprotection Committee - RPC/2003/XXXVIII/137 (May 2003)



THE INDUCED RADIOACTIVITY IN THE FORWARD SHIELDING AND SEMICONDUCTOR TRACKER OF THE ATLAS DETECTOR
(file in pdf-format)
I. Bedajanek et al.
Submitted to the Tenth International Conference on Radiation Shielding (ICRS-10) and the Thirteen Topical Meeting on Radiation Protection and Shielding (RPS-2004), Funchal, Portugal, May 2004.



ACTIVATION DOSERATE DURING ACCESS TO THE INNER DETECTOR (the entire file in pdf-format)
Report by V.A. Klimanov, E.I. Kulakova, M.N. Morev and V.K. Sakharov (May 2004)

TEXT

Plots by V. Hedberg from the above calculation:



ADDENDUM 1: (ID + VI + VA + LAr Encap) and (ID + VI + VA) and (ID + VI) and (ID)



Plots by V. Hedberg from the above calculation:



ADDENDUM 2: VA beampipe



Plots by V. Hedberg from the above calculation:



ADDENDUM 3: Pixel detector + Pixel support tube + VI beampipe



Plots by V. Hedberg from the above calculation:



ADDENDUM 4: LAr Encap and LAr barrel

Plots by V. Hedberg from the above calculation:



ADDENDUM 5: (ID with TRT C removed) and (ID with TRT C + Pixel detector removed)

Plots by V. Hedberg from the above calculation:



ADDENDUM 6: ID with only TRT barrel and SCT barrel in place

Plots by V. Hedberg from the above calculation:



ADDENDUM 7: The pixel detector without the pixel support tube. With and without the VI beampipe.

Plots by V. Hedberg from the above calculation:






ACTIVATION DOSERATE DURING ACCESS TO THE INNER DETECTOR
(file in html-format)
The old inner detector report by Morev et al. with the old description of PP1 (from 2002).


Back to the ATLAS home page

Back to the activation page.